Quotation on request

Gel-seal HEPA supply outlets

HEPA supply air outlets with a gel-seal channel that locks the filter frame against the housing knife edge for a leak-tight seal, in top-feed and side-feed versions with an optional regulating damper.

Description

A gel-seal HEPA supply outlet (gel-seal HEPA box) delivers filtered air into high-cleanliness spaces through a HEPA filter seated in a liquid gel channel. The filter frame sits in a gel potting groove that mates with the knife edge around the housing, forming an airtight seal and preventing bypass leakage; because the gel does not stick to the knife edge, the filter can be pulled and replaced from below the ceiling without dismantling the housing, which keeps maintenance time and cost down. The diffuser plate and filter are easy to remove and refit. The source rates filtration of 0.3 um and larger particles at 99.99%. Outlets are available in top-feed and side-feed versions; five sizes in each cover airflows from 500 to 3000 m3/h at an average velocity of 0.9-1.1 m/s, and a regulating damper can be fitted as an option.

Features

  • Gel-seal channel with housing knife edge: airtight seal and no bypass leakage.
  • Filter replaced from below the ceiling without removing the housing; gel stays off the knife edge.
  • Filtration of 0.3 um and larger particles rated at 99.99%.
  • Top-feed and side-feed versions; five sizes each covering 500-3000 m3/h.
  • Optional regulating damper for airflow balancing.

Applications

  • Hospitals and biological pharmaceutical clean areas
  • Semiconductor and LCD manufacturing
  • Precision machinery and optics production
  • Terminal supply air for high-cleanliness ventilation systems

Materials, performance and parameters

Catalogue data for this family.

Catalogue values describe the family. The quotation for a configuration is the binding document.

ModelFeed typeHousing size (mm)Filter size (mm)Airflow (m3/h)Average velocity (m/s)Flange opening (mm)
HU-C01Top feed460 x 460 x 250390 x 390 x 905000.9-1.1200 x 200
HU-C02Top feed594 x 594 x 250524 x 524 x 9010000.9-1.1320 x 200
HU-C03Top feed740 x 740 x 250670 x 670 x 9015000.9-1.1400 x 200
HU-C04Top feed1035 x 730 x 250965 x 660 x 9020000.9-1.1500 x 200
HU-C05Top feed1290 x 730 x 2501220 x 660 x 9030000.9-1.1500 x 300
HU-D01Side feed460 x 460 x 400390 x 390 x 905000.9-1.1200 x 200
HU-D02Side feed594 x 594 x 400524 x 524 x 9010000.9-1.1320 x 200
HU-D03Side feed740 x 740 x 400670 x 670 x 9015000.9-1.1400 x 200
HU-D04Side feed1035 x 730 x 400965 x 660 x 9020000.9-1.1500 x 200
HU-D05Side feed1290 x 730 x 5001220 x 660 x 9030000.9-1.1500 x 300

The source image lists two sub-tables; they are merged here with a feed-type column. C models are top-feed, D models side-feed. Values that appear once across all models are repeated on each row. Source model codes carried a factory series prefix that was removed; C01-C05 and D01-D05 are size classes, not yet confirmed type designations. A regulating damper is optional.

Supply scope

What is supplied, and what stays with the buyer.

  • Outlet supplied as a fixed configuration by feed type, housing size, filter grade and damper option, confirmed before quotation.
  • Quoted with the housing, gel-seal HEPA filter, diffuser plate and flanged connection; replacement filters are listed per order.
  • Ceiling opening preparation, mounting, sealing and duct connection on site stay with the buyer or the buyer's contractor.

Configurations

Fixed configurations that can be quoted.

A configuration code fixes the dimensions, electrical data, materials and documents. Quote requests that reference a code skip the specification round.

Configurations for this family are quoted on request.

What we need to quote

Inputs that fix the configuration.

  1. 01

    Required airflow and the duct connection size at the outlet

  2. 02

    Feed type (top or side) and the available plenum or duct space above the ceiling

  3. 03

    Filter grade required (for example H13 or H14 to EN 1822, or the local equivalent)

  4. 04

    Whether a regulating damper is needed, and the ceiling type

  5. 05

    Quantity and destination country or port

Documents

What ships with the quotation and the goods.

Documents are tied to configurations. Items marked as sent with the quotation are shared with qualified enquiries and are not published here.

  • Specification sheetSpecification sheet
    Being prepared

Packing and spare parts

Freight planning and first-line maintenance.

Packing

Packing data per unit is stated with each quoted configuration.

Spare parts

Spare parts are listed with each quoted configuration.

Request a quotation

Quote gel-seal hepa supply outlets as a fixed configuration.

A quotable request names the product family, the key specifications or the fact that they are still open, the quantity, the destination and who will install on site.

Request a quote for gel-seal hepa supply outlets