Air filters & filter units
Coarse filters
Washable mesh-panel coarse filters in stainless steel, nylon and aluminium for the first filtration stage of air handling units, holding back large dust before finer stages.
Quotation on request
Product reference photo · Configuration to confirm
The photograph does not define the quoted configuration. Request the drawings and documents for your requirements.
Air filters & filter units
Fan-powered chemical filtration units with a sealed plenum and slide-out filter modules, configured per project with primary, medium, HEPA, activated-carbon or chemical filter stages; duct connection and commissioning are done by the installer.
Price indicationOn quotation
Quotation on request. Configuration and availability are confirmed with your quotation.
DEFINE THE REQUIREMENT
Start with what you know. These inputs describe your project; the quoted configuration is confirmed separately.
TECHNICAL PARAMETERS
Catalogue values describe the family. The quotation for a configuration is the binding document.
Scroll sideways or focus the table and use the arrow keys. The identifying column stays in view.
| Model | Box size (mm) | Airflow (m3/h) | Motor power (W) |
|---|---|---|---|
| XFX-A01 | 2800x1350x1200 | 1700 | 3000 |
| XFX-A02 | 2800x1350x1200 | 3400 | 3000 |
| XFX-A03 | 3000x1450x1200 | 5100 | 4000 |
| XFX-A04 | 3200x1750x1200 | 6800 | 5000 |
Plenum in powder-coated cold-rolled steel or stainless steel; first and second filter stage resistance 0-500 Pa each depending on the filter combination; filter stages in combinations per project.
ABOUT THIS EQUIPMENT
A chemical filter unit is a fan-powered air handling unit built around a sealed plenum and slide-out filter modules. The housing is powder-coated cold-rolled steel - the diffuser plate can be stainless steel - acid-washed and powder-coated for corrosion resistance, so the unit stays light and rigid. Each filter stage is sealed against the housing, and the stage resistance is 0-500 Pa depending on the filter combination. Filter stages are combined per project: primary, medium, HEPA, activated carbon, chemical filter, ionizer or ozone generator. Fans and airflow are configured to the project, with models covering 1700 to 6800 m3/h in the source table. The compact layout runs at low noise and the slide-out modules make replacement straightforward.
SCOPE TO CONFIRM
Unit with fan set, plenum, filter stages and control, quoted as a fixed configuration per model and filter combination.
Quoted with filter combination, stage resistance figures and external static pressure.
Duct connection, suspension, electrical hook-up and commissioning on site stay with the buyer's installer.
PACKING & DELIVERY
Include your destination, delivery port and packing requirements in the enquiry. Packed dimensions, weight, shipping scope and lead time are confirmed for the quoted configuration.
Spare parts are listed with each quoted configuration.