Air filters & filter units

Low-resistance filter units

Low-initial-resistance medium/high-efficiency filter units for fan-coil and air-handling applications in healthcare rooms, in casing sizes from 400 to 1600 m3/h.

  • Initial resistance 20 Pa at rated airflow, 15 Pa at the reduced airflow point.
  • Filtration efficiency above 80% at 0.5 µm (source-rated).
  • Lower fan energy and longer replacement interval than a conventional filter at a similar duty.

Price indicationOn quotation

Quotation on request. Configuration and availability are confirmed with your quotation.

DEFINE THE REQUIREMENT

Your project requirements

Start with what you know. These inputs describe your project; the quoted configuration is confirmed separately.

  • Rated airflow and available resistance budget of the air-handling unit or fan-coil
  • Holding frame / installation interface dimensions
  • Required efficiency class at the specified particle size
  • Quantity and replacement cycle
  • Destination country or port

TECHNICAL PARAMETERS

Review the details. Confirm your configuration.

Catalogue values describe the family. The quotation for a configuration is the binding document.

Overall size W x H x D (mm)
550x1150x300
Filter size W x H x D (mm)
500x1100x96
Rated airflow / initial resistance (m3/h)/(Pa)
1600/20
Face velocity (m/s)
0.8
View complete parameter table

Scroll sideways or focus the table and use the arrow keys. The identifying column stays in view.

ModelOverall size W x H x D (mm)Filter size W x H x D (mm)Rated airflow / initial resistance (m3/h)/(Pa)Face velocity (m/s)Filter area (m2)Resistance at other airflows (m3/h)/(Pa)Efficiency at 0.5 µm
1600550x1150x300500x1100x961600/200.87.61200/15; 2000/25>80%
1500550x1050x300500x1000x961500/200.86.81125/15; 1875/25>80%
1200550x950x300500x900x961200/200.86.1900/15; 1500/25>80%
1000550x750x300500x700x961000/200.84.8750/15; 1250/25>80%
800550x550x300500x500x96800/200.83.4600/15; 1000/25>80%
600500x550x300450x500x96600/200.83.1450/15; 750/25>80%
500450x550x300400x500x96500/200.82.7375/15; 625/25>80%
400350x550x300300x500x96400/200.82300/15; 500/25>80%

Rows identify rated airflow in m3/h. Other sizes and efficiencies are quoted on request.

Configurations for this family are quoted on request.
Status
Quotation on request
Minimum order
Stated per quotation
Lead time
Stated per quotation

ABOUT THIS EQUIPMENT

Built around the requirement.

A low-resistance medium/high-efficiency filter unit combines a low-resistance media pack with its holding frame as one unit for fan-coil and air-handling applications. The media keeps the initial resistance low — 20 Pa at rated airflow and 15 Pa at the reduced airflow point in the table — while the source rates filtration efficiency above 80% at 0.5 µm. The low pressure drop reduces fan energy and makes installation and replacement lighter work, and the replacement interval is longer than that of a conventional filter at a similar duty. Eight casing sizes cover rated airflow from 400 to 1600 m3/h, and custom sizes and efficiencies are available on request. Typical locations are hospital clinics, dressing and examination rooms, emergency rooms and other healthcare areas served by fan-coil units.

Features

  • Initial resistance 20 Pa at rated airflow, 15 Pa at the reduced airflow point.
  • Filtration efficiency above 80% at 0.5 µm (source-rated).
  • Lower fan energy and longer replacement interval than a conventional filter at a similar duty.
  • Eight casing sizes, rated airflow 400-1600 m3/h.
  • Custom sizes and efficiencies available on request.

Applications

  • Hospital clinics, dressing and examination rooms
  • Emergency rooms and hospital fan-coil systems
  • Other healthcare areas needing medium/high-efficiency filtration at low resistance

SCOPE TO CONFIRM

Agree what comes with it.

Filter unit with media pack and holding frame, quoted per model against the air-handling unit or fan-coil size.

Quoted with dimensioned outline drawing and packing data.

Installation into the air-handling unit or fan-coil access frame on site is carried out by the buyer or the buyer's service provider.

PACKING & DELIVERY

Plan the handover.

Include your destination, delivery port and packing requirements in the enquiry. Packed dimensions, weight, shipping scope and lead time are confirmed for the quoted configuration.

Spare parts

Spare parts are listed with each quoted configuration.

Product reference photo · Configuration to confirm

Low-resistance filter unitsRequest a Quote →

YOUR EQUIPMENT LIST

Your Quote List