Quotation on request

Low-resistance fine filters

High-medium-efficiency filters with very low initial resistance for ventilation systems with little spare fan pressure, such as hospital diagnostic and treatment rooms.

Description

Low-resistance fine filters are high-medium-efficiency panel filters built to add filtration where the ventilation system has little spare fan pressure. The source table lists initial resistance around 20 Pa at rated airflow — far below a HEPA panel of similar size — with efficiency above 80 % at 0.5 µm. They suit continuous operation in hospital functional rooms such as consulting, treatment, dialysis and preparation rooms, where finer filtration is wanted without rewinding the air handling unit.

Features

  • Initial resistance around 20 Pa at rated airflow per the source table.
  • Efficiency above 80 % at 0.5 µm per the source table.
  • Slim 300 mm housings sized for ceiling or wall-mounted filter units.
  • Suits continuous operation with low system pressure drop.

Applications

  • Hospital consulting, treatment, dialysis and preparation rooms
  • Wards and other areas where finer filtration is added without extra fan pressure
  • Offices, schools and laboratories with low-resistance ventilation requirements

Materials, performance and parameters

Catalogue data for this family.

Catalogue values describe the family. The quotation for a configuration is the binding document.

ModelHousing size W×H×D (mm)Filter size W×H×D (mm)Rated airflow / initial resistance (m³/h)/(Pa)Face velocity (m/s)Media area (m²)Airflow / resistance 1 (m³/h)/(Pa)Airflow / resistance 2 (m³/h)/(Pa)Efficiency at 0.5 µm
BAC-1600550×1150×300500×1100×961600/200.87.61200/152000/25>80 %
BAC-1500550×1050×300500×1000×961500/200.86.81125/151875/25>80 %
BAC-1200550×950×300500×900×961200/200.86.1900/151500/25>80 %
BAC-1000550×750×300500×700×961000/200.84.8750/151250/25>80 %
BAC-800550×550×300500×500×96800/200.83.4600/151000/25>80 %
BAC-600500×550×300450×500×96600/200.83.1450/15750/25>80 %
BAC-500450×550×300400×500×96500/200.82.7375/15625/25>80 %
BAC-400350×550×300300×500×96400/200.82300/15500/25>80 %

Transcribed from the source catalogue parameter table. The source notes that sizes and efficiencies outside this list are available on request.

Supply scope

What is supplied, and what stays with the buyer.

  • Filter elements in the confirmed size against the housing size listed above.
  • Housing or filter-unit selection stays with the buyer unless quoted together.
  • Installation and post-installation verification stay with the buyer.

Configurations

Fixed configurations that can be quoted.

A configuration code fixes the dimensions, electrical data, materials and documents. Quote requests that reference a code skip the specification round.

Configurations for this family are quoted on request.

What we need to quote

Inputs that fix the configuration.

  1. 01

    Housing size or the filter unit model the element must fit

  2. 02

    Rated airflow of the system and the available spare fan pressure

  3. 03

    Efficiency target and any microbial control requirement of the room

  4. 04

    Quantity and destination country or port

Documents

What ships with the quotation and the goods.

Documents are tied to configurations. Items marked as sent with the quotation are shared with qualified enquiries and are not published here.

  • Specification sheetSpecification sheet
    Being prepared

Packing and spare parts

Freight planning and first-line maintenance.

Packing

Packing data per unit is stated with each quoted configuration.

Spare parts

Spare parts are listed with each quoted configuration.

Request a quotation

Quote low-resistance fine filters as a fixed configuration.

A quotable request names the product family, the key specifications or the fact that they are still open, the quantity, the destination and who will install on site.

Request a quote for low-resistance fine filters