Air supply & filter housings

Gel-seal HEPA supply outlets

HEPA supply air outlets with a gel-seal channel that locks the filter frame against the housing knife edge for a leak-tight seal, in top-feed and side-feed versions with an optional regulating damper.

  • Gel-seal channel with housing knife edge: airtight seal and no bypass leakage.
  • Filter replaced from below the ceiling without removing the housing; gel stays off the knife edge.
  • Filtration of 0.3 um and larger particles rated at 99.99%.

Price indicationOn quotation

Quotation on request. Configuration and availability are confirmed with your quotation.

DEFINE THE REQUIREMENT

Your project requirements

Start with what you know. These inputs describe your project; the quoted configuration is confirmed separately.

  • Required airflow and the duct connection size at the outlet
  • Feed type (top or side) and the available plenum or duct space above the ceiling
  • Filter grade required (for example H13 or H14 to EN 1822, or the local equivalent)
  • Whether a regulating damper is needed, and the ceiling type
  • Quantity and destination country or port

TECHNICAL PARAMETERS

Review the details. Confirm your configuration.

Catalogue values describe the family. The quotation for a configuration is the binding document.

Filter size (mm)
390 x 390 x 90
Airflow (m3/h)
500
Average velocity (m/s)
0.9-1.1
View complete parameter table

Scroll sideways or focus the table and use the arrow keys. The identifying column stays in view.

Feed type / housing size (mm)Filter size (mm)Airflow (m3/h)Average velocity (m/s)Flange opening (mm)
Top feed / 460 x 460 x 250390 x 390 x 905000.9-1.1200 x 200
Top feed / 594 x 594 x 250524 x 524 x 9010000.9-1.1320 x 200
Top feed / 740 x 740 x 250670 x 670 x 9015000.9-1.1400 x 200
Top feed / 1035 x 730 x 250965 x 660 x 9020000.9-1.1500 x 200
Top feed / 1290 x 730 x 2501220 x 660 x 9030000.9-1.1500 x 300
Side feed / 460 x 460 x 400390 x 390 x 905000.9-1.1200 x 200
Side feed / 594 x 594 x 400524 x 524 x 9010000.9-1.1320 x 200
Side feed / 740 x 740 x 400670 x 670 x 9015000.9-1.1400 x 200
Side feed / 1035 x 730 x 400965 x 660 x 9020000.9-1.1500 x 200
Side feed / 1290 x 730 x 5001220 x 660 x 9030000.9-1.1500 x 300

Top-feed and side-feed versions are listed by housing size. A regulating damper is optional.

Configurations for this family are quoted on request.
Status
Quotation on request
Minimum order
Stated per quotation
Lead time
Stated per quotation

ABOUT THIS EQUIPMENT

Built around the requirement.

A gel-seal HEPA supply outlet (gel-seal HEPA box) delivers filtered air into high-cleanliness spaces through a HEPA filter seated in a liquid gel channel. The filter frame sits in a gel potting groove that mates with the knife edge around the housing, forming an airtight seal and preventing bypass leakage; because the gel does not stick to the knife edge, the filter can be pulled and replaced from below the ceiling without dismantling the housing, which keeps maintenance time and cost down. The diffuser plate and filter are easy to remove and refit. The source rates filtration of 0.3 um and larger particles at 99.99%. Outlets are available in top-feed and side-feed versions; five sizes in each cover airflows from 500 to 3000 m3/h at an average velocity of 0.9-1.1 m/s, and a regulating damper can be fitted as an option.

Features

  • Gel-seal channel with housing knife edge: airtight seal and no bypass leakage.
  • Filter replaced from below the ceiling without removing the housing; gel stays off the knife edge.
  • Filtration of 0.3 um and larger particles rated at 99.99%.
  • Top-feed and side-feed versions; five sizes each covering 500-3000 m3/h.
  • Optional regulating damper for airflow balancing.

Applications

  • Hospitals and biological pharmaceutical clean areas
  • Semiconductor and LCD manufacturing
  • Precision machinery and optics production
  • Terminal supply air for high-cleanliness ventilation systems

SCOPE TO CONFIRM

Agree what comes with it.

Outlet supplied as a fixed configuration by feed type, housing size, filter grade and damper option, confirmed before quotation.

Quoted with the housing, gel-seal HEPA filter, diffuser plate and flanged connection; replacement filters are listed per order.

Ceiling opening preparation, mounting, sealing and duct connection on site stay with the buyer or the buyer's contractor.

PACKING & DELIVERY

Plan the handover.

Include your destination, delivery port and packing requirements in the enquiry. Packed dimensions, weight, shipping scope and lead time are confirmed for the quoted configuration.

Spare parts

Spare parts are listed with each quoted configuration.

Product reference photo · Configuration to confirm

Gel-seal HEPA supply outletsRequest a Quote →