Product reference photo · Configuration to confirm
The photograph does not define the quoted configuration. Request the drawings and documents for your requirements.
Air & decontamination showers
Two-side air showers
Personnel air showers with HEPA-filtered air jetted from nozzles on two sides, used at cleanroom entrances to remove dust from clothing before entry; the buyer's contractor positions and connects the cabin on site.
Quotation on request. Configuration and availability are confirmed with your quotation.
DEFINE THE REQUIREMENT
Your project requirements
Start with what you know. These inputs describe your project; the quoted configuration is confirmed separately.
Number of persons per cycle and required cabin length
External and internal dimensional limits at the installation opening
Power supply available on site (standard configuration is 380 V/50 Hz)
Body material and nozzle count preference
Quantity and destination country or port
TECHNICAL PARAMETERS
Review the details. Confirm your configuration.
Catalogue values describe the family. The quotation for a configuration is the binding document.
Detailed technical parameters are confirmed for the requested configuration.
Configurations for this family are quoted on request.
Status
Quotation on request
Minimum order
Stated per quotation
Lead time
Stated per quotation
ABOUT THIS EQUIPMENT
Built around the requirement.
A two-side air shower is a personnel decontamination cabin installed at the entrance of a clean area. Clean air filtered through a final HEPA stage is jetted onto the person from stainless steel adjustable nozzles on two sides, removing dust particles from clothing quickly and reducing the particle load carried into the cleanroom. The cabin is PLC controlled with an LED display showing the shower cycle progress and the two-door interlock status. Modular cabin sections can be assembled to different shower lengths. Nozzle outlet speed is above 25 m/s and the air speed reaching the body is above 18 m/s.
Cabin supplied as a fixed configuration by external dimensions, internal dimensions, nozzle count and door arrangement.
Quoted with fan, primary and HEPA filters, nozzle set, PLC control panel and interlock as listed in the configuration.
Positioning on site, power connection and commissioning are carried out by the buyer or the buyer's contractor.
PACKING & DELIVERY
Plan the handover.
Include your destination, delivery port and packing requirements in the enquiry. Packed dimensions, weight, shipping scope and lead time are confirmed for the quoted configuration.
Spare parts
Spare parts are listed with each quoted configuration.
RELATED EQUIPMENT
Consider the interfaces.
Dimensional and functional compatibility need to be confirmed for your configuration.