Product reference photo · Configuration to confirm
The photograph does not define the quoted configuration. Request the drawings and documents for your requirements.
Air supply & filter housings
HEPA terminal housings
Terminal HEPA filter housings for cleanroom ceiling grids, in top-adjustable, replaceable-media and disposable integrated versions; the housing, filter class and ceiling interface are fixed per configuration, and duct connection is done by the installer.
Top-adjustable version: filter position adjusted from above; side or top duct entry.
Replaceable-media version: media pack replaced from the room side, frame stays in the ceiling.
Disposable integrated version: sealed frame-and-filter unit with fine glass-fibre media.
Quotation on request. Configuration and availability are confirmed with your quotation.
DEFINE THE REQUIREMENT
Your project requirements
Start with what you know. These inputs describe your project; the quoted configuration is confirmed separately.
Ceiling type and module size (T-bar, sandwich panel, light steel or lay-in)
Required airflow per outlet and duct inlet size
Filter class (H13 or H14) and housing version preferred
Power-free or damper-related options such as the top-adjustable mechanism
Quantity and destination country or port
TECHNICAL PARAMETERS
Review the details. Confirm your configuration.
Catalogue values describe the family. The quotation for a configuration is the binding document.
Rated airflow / initial resistance (m3/h / Pa)
1000/160
Face velocity (m/s)
0.73
Alt. airflow / resistance (m3/h / Pa)
600/90 - 1450/235
Rated airflow / initial resistance (m3/h / Pa)
1450/155
Face velocity (m/s)
0.72
Alt. airflow / resistance (m3/h / Pa)
900/90 - 2200/235
Rated airflow / initial resistance (m3/h / Pa)
1920/155
Face velocity (m/s)
0.72
Alt. airflow / resistance (m3/h / Pa)
1200/90 - 2950/235
Rated airflow / initial resistance (m3/h / Pa)
1230/155
Face velocity (m/s)
0.92
Alt. airflow / resistance (m3/h / Pa)
600/70 - 1450/190
Rated airflow / initial resistance (m3/h / Pa)
1810/155
Face velocity (m/s)
0.90
Alt. airflow / resistance (m3/h / Pa)
900/70 - 2200/190
Rated airflow / initial resistance (m3/h / Pa)
1500/155
Face velocity (m/s)
1.13
Alt. airflow / resistance (m3/h / Pa)
600/60 - 1800/190
Rated airflow / initial resistance (m3/h / Pa)
2230/155
Face velocity (m/s)
1.11
Alt. airflow / resistance (m3/h / Pa)
900/60 - 2700/190
Rated airflow / initial resistance (m3/h / Pa)
2950/155
Face velocity (m/s)
1.10
Alt. airflow / resistance (m3/h / Pa)
1200/60 - 3600/190
View complete parameter table
Scroll sideways or focus the table and use the arrow keys. The identifying column stays in view.
Model
External W x H x D (mm)
Rated airflow / initial resistance (m3/h / Pa)
Face velocity (m/s)
Filter area (m2)
Alt. airflow / resistance (m3/h / Pa)
Recommended final resistance (Pa)
Filter class (EN 1822)
B59-001
610x610x120
1000/160
0.73
10.9
600/90 - 1450/235
400
H13
B59-002
610x915x120
1450/155
0.72
16.1
900/90 - 2200/235
400
H13
B59-003
610x1220x120
1920/155
0.72
21.3
1200/90 - 2950/235
400
H13
B59-004
610x610x150
1230/155
0.92
13.6
600/70 - 1450/190
400
H13
B59-005
610x915x150
1810/155
0.90
20.1
900/70 - 2200/190
400
H13
B59-006
610x610x220
1500/155
1.13
16.8
600/60 - 1800/190
400
H13
B59-007
610x915x220
2230/155
1.11
24.8
900/60 - 2700/190
400
H13
B59-008
610x1220x220
2950/155
1.10
32.8
1200/60 - 3600/190
400
H13
Table covers the disposable integrated version. Alternative airflow/resistance pairs are the low and high operating points listed here. Non-standard sizes and H13/H14 efficiency available on request. Top-adjustable and replaceable-media versions are sized by ceiling module and filter face, quoted after confirmation.
Configurations for this family are quoted on request.
Status
Quotation on request
Minimum order
Stated per quotation
Lead time
Stated per quotation
ABOUT THIS EQUIPMENT
Built around the requirement.
HEPA terminal housings mount the final HEPA filter at the supply-air end of a cleanroom air-conditioning system. Three versions are offered. The top-adjustable housing sets the filter face relative to the ceiling from above, with side or top air entry, a compact powder-coated steel housing and a diffuser plate; the filter is reachable and replaceable from below. The replaceable-media integrated housing keeps the frame in the ceiling and replaces only the media pack from the room side, using special retaining clips; the anodized aluminium extrusion frame suits T-bar, sandwich-panel, light-steel and lay-in ceiling types, with three inlet sizes and an optional stainless outlet plate. The disposable integrated housing is a sealed frame-and-filter unit with a fine glass-fibre media pack capturing particles of 0.3 µm and above; the anodized aluminium frame is closed-cell sealed, and the unit is replaced as one piece at the end of media life. The source rates B1-class fire performance for the 10 mm PE insulation on the disposable version and lists H13 filter class as standard, with custom sizes and H13/H14 efficiency on request.
Features
Top-adjustable version: filter position adjusted from above; side or top duct entry.
Replaceable-media version: media pack replaced from the room side, frame stays in the ceiling.
Disposable integrated version: sealed frame-and-filter unit with fine glass-fibre media.
Filter class H13 to EN 1822 as standard; H13/H14 and non-standard sizes on request.
Anodized aluminium frames for T-bar, sandwich-panel, light-steel and lay-in ceilings.
Diffuser plate spreads supply air evenly into the room.
Applications
Pharmaceutical and biopharmaceutical cleanrooms
Hospital operating rooms and laboratories
Microelectronics and semiconductor plants
Food processing clean areas
Optics, film and fibre-equipment production
SCOPE TO CONFIRM
Agree what comes with it.
Terminal housing with HEPA filter stage and diffuser plate, quoted as a fixed configuration by version, ceiling module and filter class.
Sealing between housing and ceiling, plus replacement media packs, listed in the quotation.
Duct connection, ceiling reinforcement and final testing on site stay with the buyer's installer.
PACKING & DELIVERY
Plan the handover.
Include your destination, delivery port and packing requirements in the enquiry. Packed dimensions, weight, shipping scope and lead time are confirmed for the quoted configuration.
Spare parts
Spare parts are listed with each quoted configuration.
RELATED EQUIPMENT
Consider the interfaces.
Dimensional and functional compatibility need to be confirmed for your configuration.