Product reference photo · Configuration to confirm
The photograph does not define the quoted configuration. Request the drawings and documents for your requirements.
Air supply & filter housings
Mesh-face HEPA outlets
Terminal HEPA supply outlets with a mesh diffuser face for cleanrooms, combining plenum box, final filter and diffuser in one unit for new builds and retrofits.
Plenum box, final HEPA filter, filter collar and mesh diffuser face in one terminal.
Even air distribution across the mesh face at 0.9-1.1 m/s face velocity.
Two casing depths: 380 mm with 90 mm filter, 500-600 mm with 220 mm filter.
Quotation on request. Configuration and availability are confirmed with your quotation.
DEFINE THE REQUIREMENT
Your project requirements
Start with what you know. These inputs describe your project; the quoted configuration is confirmed separately.
Required airflow per outlet and room cleanliness class
Ceiling or wall opening size and installation depth available
Duct flange size and position
Filter size and efficiency class required by the project specification
Whether the down-adjustment damper is required
Quantity and destination country or port
TECHNICAL PARAMETERS
Review the details. Confirm your configuration.
Catalogue values describe the family. The quotation for a configuration is the binding document.
Casing size (mm)
390x390x380
Filter size (mm)
320x320x90
Airflow (m3/h)
500
Face velocity (m/s)
0.9-1.1
Casing size (mm)
554x554x380
Filter size (mm)
484x484x90
Airflow (m3/h)
1000
Face velocity (m/s)
0.9-1.1
Casing size (mm)
680x680x380
Filter size (mm)
610x610x90
Airflow (m3/h)
1500
Face velocity (m/s)
0.9-1.1
Casing size (mm)
680x1290x380
Filter size (mm)
610x1220x90
Airflow (m3/h)
3000
Face velocity (m/s)
0.9-1.1
Casing size (mm)
390x390x500
Filter size (mm)
320x320x220
Airflow (m3/h)
500
Face velocity (m/s)
0.9-1.1
Casing size (mm)
554x554x500
Filter size (mm)
484x484x220
Airflow (m3/h)
1000
Face velocity (m/s)
0.9-1.1
Casing size (mm)
680x680x500
Filter size (mm)
610x610x220
Airflow (m3/h)
1500
Face velocity (m/s)
0.9-1.1
Casing size (mm)
680x1290x600
Filter size (mm)
610x1220x220
Airflow (m3/h)
3000
Face velocity (m/s)
0.9-1.1
View complete parameter table
Scroll sideways or focus the table and use the arrow keys. The identifying column stays in view.
Model
Casing size (mm)
Filter size (mm)
Airflow (m3/h)
Face velocity (m/s)
Flange size (mm)
HU-A01
390x390x380
320x320x90
500
0.9-1.1
200x200
HU-A02
554x554x380
484x484x90
1000
0.9-1.1
320x200
HU-A03
680x680x380
610x610x90
1500
0.9-1.1
400x200
HU-A04
680x1290x380
610x1220x90
3000
0.9-1.1
500x300
HU-B01
390x390x500
320x320x220
500
0.9-1.1
200x200
HU-B02
554x554x500
484x484x220
1000
0.9-1.1
320x200
HU-B03
680x680x500
610x610x220
1500
0.9-1.1
400x200
HU-B04
680x1290x600
610x1220x220
3000
0.9-1.1
500x300
A-series casing depth 380 mm, B-series 500-600 mm. An optional down-adjustment damper can be fitted.
Configurations for this family are quoted on request.
Status
Quotation on request
Minimum order
Stated per quotation
Lead time
Stated per quotation
ABOUT THIS EQUIPMENT
Built around the requirement.
A mesh-face HEPA outlet is a ceiling or wall terminal unit for cleanrooms, built as a plenum box with a final HEPA filter, a filter collar and a mesh diffuser face with a perforated diffusion plate. The built-in HEPA stage removes dust particles, bacteria and other contaminants from the supply air, and the mesh face spreads the air evenly to avoid dead zones or local over-blowing. Airflow is set at 500 to 3000 m3/h per unit with a face velocity of 0.9-1.1 m/s. Two casing depths are offered — 380 mm with a 90 mm filter, and 500-600 mm with a 220 mm filter — and an optional down-adjustment damper can be fitted for airflow balancing. The design suits new builds and retrofits across cleanliness classes in pharmaceutical, healthcare, electronics and chemical facilities.
Features
Plenum box, final HEPA filter, filter collar and mesh diffuser face in one terminal.
Even air distribution across the mesh face at 0.9-1.1 m/s face velocity.
Two casing depths: 380 mm with 90 mm filter, 500-600 mm with 220 mm filter.
Four sizes per series with airflow from 500 to 3000 m3/h.
Optional down-adjustment damper; detachable construction for filter replacement.
Applications
Cleanroom supply-air terminals in pharmaceutical and healthcare facilities
Electronics and chemical cleanrooms
New-build and retrofit projects across cleanliness classes
SCOPE TO CONFIRM
Agree what comes with it.
Outlet unit with plenum box, final HEPA filter, filter collar, mesh diffuser face and flange, quoted per model.
Quoted with dimensioned outline drawing, filter specification and packing data.
Duct connection, ceiling or wall sealing and installation on site are carried out by the buyer or the buyer's contractor.
PACKING & DELIVERY
Plan the handover.
Include your destination, delivery port and packing requirements in the enquiry. Packed dimensions, weight, shipping scope and lead time are confirmed for the quoted configuration.
Spare parts
Spare parts are listed with each quoted configuration.
RELATED EQUIPMENT
Consider the interfaces.
Dimensional and functional compatibility need to be confirmed for your configuration.