Product reference photo · Configuration to confirm
The photograph does not define the quoted configuration. Request the drawings and documents for your requirements.
Air supply & filter housings
Standard HEPA supply outlets
Standard HEPA supply outlets (terminal filter boxes with plenum and diffuser plate) for class 1000 to 100000 air-conditioning systems, sized by box, filter face, airflow and duct flange; installed in the ceiling by the buyer's contractor.
Terminal HEPA filtration with separatorless mini-pleat filter in a galvanized or powder-coated steel housing.
Diffuser plate for even room air distribution without dead corners.
Low-noise operation; face velocity 0.9-1.1 m/s across the listed range.
Quotation on request. Configuration and availability are confirmed with your quotation.
DEFINE THE REQUIREMENT
Your project requirements
Start with what you know. These inputs describe your project; the quoted configuration is confirmed separately.
Required airflow per outlet and number of outlets
Ceiling module and available plenum depth (380 mm or 500-600 mm series)
Duct inlet size and connection side
Filter class required (standard or higher efficiency on request)
Quantity and destination country or port
TECHNICAL PARAMETERS
Review the details. Confirm your configuration.
Catalogue values describe the family. The quotation for a configuration is the binding document.
Box size (mm)
390x390x380
Filter size (mm)
320x320x90
Airflow (m3/h)
500
Mean face velocity (m/s)
0.9-1.1
Box size (mm)
554x554x380
Filter size (mm)
484x484x90
Airflow (m3/h)
1000
Mean face velocity (m/s)
0.9-1.1
Box size (mm)
680x680x380
Filter size (mm)
610x610x90
Airflow (m3/h)
1500
Mean face velocity (m/s)
0.9-1.1
Box size (mm)
680x1290x380
Filter size (mm)
610x1220x90
Airflow (m3/h)
3000
Mean face velocity (m/s)
0.9-1.1
Box size (mm)
390x390x500
Filter size (mm)
320x320x220
Airflow (m3/h)
500
Mean face velocity (m/s)
0.9-1.1
Box size (mm)
554x554x500
Filter size (mm)
484x484x220
Airflow (m3/h)
1000
Mean face velocity (m/s)
0.9-1.1
Box size (mm)
680x680x600
Filter size (mm)
610x610x220
Airflow (m3/h)
1500
Mean face velocity (m/s)
0.9-1.1
Box size (mm)
680x1290x600
Filter size (mm)
610x1220x220
Airflow (m3/h)
3000
Mean face velocity (m/s)
0.9-1.1
View complete parameter table
Scroll sideways or focus the table and use the arrow keys. The identifying column stays in view.
Model
Box size (mm)
Filter size (mm)
Airflow (m3/h)
Mean face velocity (m/s)
Inlet flange (mm)
HU-A01
390x390x380
320x320x90
500
0.9-1.1
200x200
HU-A02
554x554x380
484x484x90
1000
0.9-1.1
320x200
HU-A03
680x680x380
610x610x90
1500
0.9-1.1
400x200
HU-A04
680x1290x380
610x1220x90
3000
0.9-1.1
500x300
HU-B01
390x390x500
320x320x220
500
0.9-1.1
200x200
HU-B02
554x554x500
484x484x220
1000
0.9-1.1
320x200
HU-B03
680x680x600
610x610x220
1500
0.9-1.1
400x200
HU-B04
680x1290x600
610x1220x220
3000
0.9-1.1
500x300
A series: 380 mm box depth with 90 mm filter. B series: 500-600 mm box depth with 220 mm filter for higher capacity. Downward-adjustable damper optional.
Configurations for this family are quoted on request.
Status
Quotation on request
Minimum order
Stated per quotation
Lead time
Stated per quotation
ABOUT THIS EQUIPMENT
Built around the requirement.
A standard HEPA supply outlet is the terminal device of a cleanroom air-conditioning system, used in class 1000, 10000 and 100000 installations. Central station air enters the plenum box, passes the final HEPA filter - typically a separatorless mini-pleat type - and is distributed into the room through a diffuser plate. The filter captures fine particles, dust and micro-organisms so the supplied air meets the room class. The unit gives an even air distribution without dead corners or swirling, runs at low noise, and opens from below for filter replacement. Two housing depths are listed: the A series with a 380 mm deep box and 90 mm deep filter, and the B series with a 500-600 mm deep box and a 220 mm deep high-capacity filter, both covering 500 to 3000 m3/h. A downward-adjustable damper can be fitted as an option.
Features
Terminal HEPA filtration with separatorless mini-pleat filter in a galvanized or powder-coated steel housing.
Diffuser plate for even room air distribution without dead corners.
Low-noise operation; face velocity 0.9-1.1 m/s across the listed range.
Filter replaced from below; housing opens without tools.
Two housing depths: 380 mm with 90 mm filter, or 500-600 mm with 220 mm filter.
Optional downward-adjustable damper.
Applications
Pharmaceutical and medical cleanrooms
Electronics and semiconductor plants
Biological laboratories
Food and beverage production areas
SCOPE TO CONFIRM
Agree what comes with it.
Outlet supplied as a fixed configuration per model: plenum box, HEPA filter, diffuser plate and gasket.
Optional damper and alternative diffuser patterns listed in the quotation.
Ceiling cut-out, suspension, duct connection and final testing on site stay with the buyer's installer.
PACKING & DELIVERY
Plan the handover.
Include your destination, delivery port and packing requirements in the enquiry. Packed dimensions, weight, shipping scope and lead time are confirmed for the quoted configuration.
Spare parts
Spare parts are listed with each quoted configuration.
RELATED EQUIPMENT
Consider the interfaces.
Dimensional and functional compatibility need to be confirmed for your configuration.